Microsoft Security Response Center guidance
Vendor revision: Nov 21, 2026Release Notes
Vulnerability intelligence
CVE-2026-99444. It is not in the current CISA KEV record we collected. That does not prove exploitation has not occurred.
Release Notes
In the Linux kernel, the following vulnerability has been resolved:
power: supply: sbs-battery: disable polling before supply teardown
The managed poll-work cancellation is registered before the power supply, so cleanup unregisters the supply before draining polling. A pending or running poller can then call power_supply_changed() on the released supply.
Commit 8d59cf3887fb ("power: supply: sbs-battery: Fix use-after-free in power_supply_changed()") moved the IRQ request after supply registration, but did not change the poll-work cancellation order.
Add a later managed action that disables and drains polling before supply teardown. Its retained disabled state prevents external-power callbacks from rearming the poll work after it has been drained.
Keep the original autocancel to initialize work before supply callbacks can run and to cover failed supply registration.
The teardown ordering issue was found by static analysis.
Source: NVD